When grease injection of Globe Valve, the problem of how much grease to inject is often ignored. After the grease gun is refueled, the operator selects the Globe Valve and the grease injection connection method, and then performs the grease injection operation. There are two situations: on the one hand, the small amount of grease injection leads to insufficient grease injection, and the sealing surface wears faster due to lack of lubricant. On the other hand, excessive grease injection causes waste. It is because the sealing capacity of different Universal Valve is not accurately calculated according to the type of Globe Valve. The sealing capacity can be calculated according to the size and type of the Globe Valve, and then the appropriate amount of grease can be reasonably injected.
About Brass Globe Valve
Pressure problems are often ignored when grease is injected into the Globe Valve. During the grease injection operation, the grease injection pressure changes regularly in peaks and valleys. If the pressure is too low, the seal leaks or fails, and if the pressure is too high, the grease injection port is blocked, and the grease inside the seal or the seal ring is locked with the valve ball and valve plate. Usually, when the grease injection pressure is too low, the injected grease flows into the bottom of the valve cavity, which usually occurs in small gate valves. If the grease injection pressure is too high, on the one hand, check the grease injection nozzle. If the grease hole is blocked, replace it according to the situation. On the other hand, if the grease is hardened, use cleaning fluid to repeatedly soften the failed sealing grease and inject new grease to replace it. In addition, the seal model and seal material also affect the grease injection pressure. Different seal forms have different grease injection pressures. Generally, the grease injection pressure of hard seals is higher than that of soft seals.
When greasing the Globe Valve, pay attention to the switch position of the Globe Valve. The Ball Valve is generally in the open position during maintenance, and it is closed for maintenance in special circumstances. Other Universal Valve cannot be treated as open positions. The Gate Valve must be in the closed position during maintenance to ensure that the grease fills the sealing groove along the sealing ring. If it is in the open position, the sealing grease directly enters the flow channel or valve cavity, causing waste.
When greasing the Globe Valve, the grease injection effect is often ignored. The pressure, grease injection amount, and switch position are normal during the grease injection operation. However, in order to ensure the grease injection effect of the Globe Valve, it is sometimes necessary to open or close the Globe Valve to check the lubrication effect and confirm that the surface of the Globe Valve ball or gate is evenly lubricated.
When injecting grease, attention should be paid to the problem of draining the valve body and the pressure relief of the plug. After the Globe Valve is pressure tested, the gas and moisture in the sealing cavity will increase due to the increase in ambient temperature. When injecting grease, drain and relieve the pressure first to facilitate the smooth progress of the grease injection. After grease injection, the air and moisture in the sealing cavity are fully replaced. Timely release of the valve cavity pressure also ensures the safe use of the Globe Valve. After the grease injection, be sure to tighten the drain and pressure relief plugs to prevent accidents.
When injecting grease, it is also necessary to observe the flushing of the Globe Valve diameter with the sealing ring seat. For example, if there is an open position interference with the ball valve, the open position limiter can be adjusted inward, and the sun is set after confirming that the diameter is straight. When adjusting the limit, you cannot only pursue the open or closed position, but also consider the overall situation. If the open position is flush and the closing position is not in place, the Globe Valve will not be closed tightly. Similarly, when adjusting the closing position, the corresponding adjustment of the open position should also be considered. Ensure the right-angle stroke of the Globe Valve.
After grease injection, the grease injection port must be sealed. Prevent impurities from entering or lipid oxidation at the grease injection port, and apply anti-rust grease to the cap to prevent rust. For the next operation and application.

Previous: Daily maintenance of Globe Valve

Next: How to maintain and maintain Globe Valve

Related Products List

Home

Product

Phone

About Us

Inquiry

We will contact you immediately

Fill in more information so that we can get in touch with you faster

Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.

Send